Fontaine Modification | NHTSA Recall #22V757000

Vehicle safety recall details from the Department of Transportation.

Description

Detailed recall information for NHTSA ID 22V757000 by Fontaine Modification. Affecting fontaine-modified 2020-2023 elgin crosswind 1 and elgin whirlwind 1 sweepers built on peterbilt 220 chassis Includes 56 affected units, Hydrostatic Pump Failure, component: EQUIPMENT, and more from the Department of Transportation.

Vehicle Make / Model

makesAndModels

fontaine-modified 2020-2023 elgin crosswind 1 and elgin whirlwind 1 sweepers built on peterbilt 220 chassis

Defect Summary

Fontaine modification (fontaine) is recalling certain fontaine-modified 2020-2023 elgin crosswind 1 and elgin whirlwind 1 sweepers built on peterbilt 220 chassis. the engine air compressor stainless steel braided supply line may rub through the oil suction tube running from the variable power divider (vpd) sump to the hydrostatic pump, causing the pump to fail.

Corrective Action

Fontaine will provide remedy instructions to elgin sweeper company dealers to reroute the air line and inspect and repair any damage, free of charge. owner notification letters were mailed october 24, 2022. owners may contact fontaine's customer service at 1-800-366-8246.

Recall Overview

NHTSA ID: 22V757000
Manufacturer: Fontaine Modification
Report Received Date: 2022-10-10T00:00:00
Subject: Hydrostatic pump failure
Component: Equipment
Potentially Affected Units: 56

Details

MFR Campaign Number: NR (Not Reported)
Recall Type: Vehicle
Defect Summary: Fontaine modification (fontaine) is recalling certain fontaine-modified 2020-2023 elgin crosswind 1 and elgin whirlwind 1 sweepers built on peterbilt 220 chassis. the engine air compressor stainless steel braided supply line may rub through the oil suction tube running from the variable power divider (vpd) sump to the hydrostatic pump, causing the pump to fail.
Consequence Summary: Hydrostatic pump failure can cause a loss of power, limiting vehicle speed, and increasing the risk of a crash.
Corrective Action: Fontaine will provide remedy instructions to elgin sweeper company dealers to reroute the air line and inspect and repair any damage, free of charge. owner notification letters were mailed october 24, 2022. owners may contact fontaine's customer service at 1-800-366-8246.

Safety Information

Fire Risk When Parked: No
Do Not Drive: No
Completion Rate: 58.18

Metadata

SID: row-znbs~wbpx-7pm3
NHTSA ID: 22V757000
Position: N/A
Created At: 1742808662
Created Meta: N/A
Updated At: 1742808662
Updated Meta: N/A
Meta: { }