Braun Industries, Inc. | NHTSA Recall #21V003000

Vehicle safety recall details from the Department of Transportation.

Description

Detailed recall information for NHTSA ID 21V003000 by Braun Industries, Inc.. Affecting 2019 and 2021 crestline ccl150 type iii e-series and 2019-2020 crestline ccl150 type i f-series and ccl150 type iii g-series ambulances Includes 61 affected units, D-Ring Installed Too Close To Mounting Flange, component: SEAT BELTS, and more from the Department of Transportation.

Vehicle Make / Model

makesAndModels

2019 and 2021 crestline ccl150 type iii e-series and 2019-2020 crestline ccl150 type i f-series and ccl150 type iii g-series ambulances

Defect Summary

Braun ambulances (braun) is recalling certain 2019 and 2021 crestline ccl150 type iii e-series and 2019-2020 crestline ccl150 type i f-series and ccl150 type iii g-series ambulances. two of the eight fastening points of the seat belt system installed in the ambulance patient compartment side-facing cpr seating position on the street-side of the vehicle may be defective. two of the threaded inserts used for the rearward retractor and shoulder belt d-ring are installed too close to a mounting flange resulting in improper crimping of the threaded insert.

Corrective Action

Braun will notify owners and dealers will inspect both seat belt anchor points and if no defect exists, no further action will be required. If the inspection shows the defect exists on one or both seat belt anchor points, your dealer will replace the defective insert(s) with nut plate(s) during the inspection, free of charge. the recall began on march 1, 2021. owners may contact braun ambulances customer service at 1-877-344-9990.

Recall Overview

NHTSA ID: 21V003000
Report Received Date: 2021-01-08T00:00:00
Subject: D-ring installed too close to mounting flange
Component: Seat Belts
Potentially Affected Units: 61

Details

MFR Campaign Number: NR (Not Reported)
Recall Type: Vehicle
Defect Summary: Braun ambulances (braun) is recalling certain 2019 and 2021 crestline ccl150 type iii e-series and 2019-2020 crestline ccl150 type i f-series and ccl150 type iii g-series ambulances. two of the eight fastening points of the seat belt system installed in the ambulance patient compartment side-facing cpr seating position on the street-side of the vehicle may be defective. two of the threaded inserts used for the rearward retractor and shoulder belt d-ring are installed too close to a mounting flange resulting in improper crimping of the threaded insert.
Consequence Summary: The improper crimping may result in partial or complete loss of effectiveness of the seat belt harness, increasing the risk of injury to the occupant in that seated position, in the event of a crash.
Corrective Action: Braun will notify owners and dealers will inspect both seat belt anchor points and if no defect exists, no further action will be required. If the inspection shows the defect exists on one or both seat belt anchor points, your dealer will replace the defective insert(s) with nut plate(s) during the inspection, free of charge. the recall began on march 1, 2021. owners may contact braun ambulances customer service at 1-877-344-9990.

Safety Information

Fire Risk When Parked: No
Do Not Drive: No
Completion Rate: 100